Code colors: BL/WH-BL, OR/WH-OR, GN/GN-WH and BR/BR-WH
Molding type, with inner and over molding.
Electrical Test:
Insulation resistance: 10MΩ Min.
Conduct Resistance: 1.5Ω Max.
Performance test:
Durability: 750 mating cycles
100% patch cord test for Cat6A, Cat6 and optional for Cat5e patch cord.
Fluke test(DSX-5000):
Run all TIA CAT 5e all channel tests+HDTDR and hdtdx (this includes TLC and CMRL);
RL Margin>7db;
NEXT margin>20db; Limit 60db, 0~150MHz;
TCL>40db (0~50MHz) and >30db (50~150MHz), Maxium 20db Spread;
CRML-No pair can completely separate from the other pairs by > 2db along the entire frequency range from 0 to 150 MHz (I.E. No CMRL pair outliers are allowed).
Identification of faults along the cable: Run HDTDR(For RL), No impedance change>+/-10% and run HDTDX(For NEXT), No impedance change>+/-10%.
Length: 0.5 to 100m (optional)
All products, includes packing materials are REACH compliant